THN 20-2413WIR

THN 20-2413WIR

  • 厂商:

    TRACOPOWER

  • 封装:

    DIP6 模块

  • 描述:

    隔离模块 直流转换器 1 输出 15V 1.33A 9V - 36V 输入

  • 数据手册
  • 价格&库存
THN 20-2413WIR 数据手册
DC/DC Railway Converter • • Compact 1” x 1” metal package • Qualification for fire behavior according to EN 45545-2 • Wide 4:1 input voltage: 9-36, 18-75, 36-160 VDC • • • • • • THN 20WIR Series, 20 Watt EN 50155 and EN 61373 approval for railway applications UL 62368-1 IEC 62368-1 Operating temperature range -40 to +65 °C without derating The THN 20WIR series is a family of ruggedized 20 Watt DC/DC converters for highest reliability in harsh environments. The converters have a wide 4:1 input range and increased resistance against electromagnetic interference, shock/viHigh efficiency up to 91% bration and thermal shock and come in a six-side shielded 1” x 1” metal package. The innovative design provides high efficiencies up to 91% and thus en3000 VDC I/O-isolation able an operating temperature range from -40 to +65°C without derating. The Protection against overload, overvoltage approvals according to standards EN 50155 and EN 61373 qualify them for and short circuit railway and transportation systems. Additional qualification for the fire behavior of components according to EN 45545-2 and the safety approval according Remote On/Off and Trim function IEC/EN 62368-1, UL62368-1 support a potential compliance test of the appli3-year product warranty cation. Built-in features like an internal EN 55032 class A filter, input undervoltage-lockout, short circuit protection, remote On/Off and output voltage trim make this series suitable for almost any application demands and thus facilitate the design-in process. Models Order Code Input Voltage Range THN 20-2410WIR THN 20-2411WIR THN 20-2412WIR THN 20-2413WIR THN 20-2415WIR THN 20-2422WIR THN 20-2423WIR THN 20-2425WIR THN 20-4810WIR THN 20-4811WIR THN 20-4812WIR THN 20-4813WIR THN 20-4815WIR THN 20-4822WIR THN 20-4823WIR THN 20-4825WIR THN 20-7210WIR THN 20-7211WIR THN 20-7212WIR THN 20-7213WIR THN 20-7215WIR THN 20-7222WIR THN 20-7223WIR THN 20-7225WIR www.tracopower.com 9 - 36 VDC (24 VDC nom.) 18 - 75 VDC (48 VDC nom.) 36 - 160 VDC (110 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC +24 VDC 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC +24 VDC 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC +24 VDC 5'500 mA 4'000 mA 1'670 mA 1'330 mA 833 mA 833 mA 667 mA 417 mA 5'500 mA 4'000 mA 1'670 mA 1'330 mA 833 mA 833 mA 667 mA 417 mA 5'500 mA 4'000 mA 1'670 mA 1'330 mA 833 mA 833 mA 667 mA 417 mA September 28, 2023 Vnom Efficiency Imax –12 VDC –15 VDC –24 VDC 833 mA 667 mA 417 mA –12 VDC –15 VDC –24 VDC 833 mA 667 mA 417 mA –12 VDC –15 VDC –24 VDC 833 mA 667 mA 417 mA typ. 88 % 89 % 89 % 89 % 91 % 89 % 90 % 91 % 89 % 90 % 89 % 90 % 91 % 89 % 90 % 91 % 88 % 90 % 90 % 90 % 91 % 90 % 90 % 91 % Page 1 / 5 THN 20WIR Series, 20 Watt Options THN-HS2 - Optional Heat Sink: www.tracopower.com/products/thn-hs2.pdf on demand - Optional Heat Sink: www.tracopower.com/products/thn-hs3.pdf (backorder with MOQ non stocking item) - Optional Heat Sink: www.tracopower.com/products/thn-hs4.pdf Input Specifications Input Current - At no load 24 Vin models: 48 Vin models: 110 Vin models: 24 Vin models: 48 Vin models: 110 Vin models: 24 Vin models: 48 Vin models: 110 Vin models: 24 Vin models: 48 Vin models: 110 Vin models: Surge Voltage Under Voltage Lockout Recommended Input Fuse Input Filter 9 mA typ. 7 mA typ. 6 mA typ. 50 VDC max. (1 s max.) 100 VDC max. (1 s max.) 185 VDC max. (1 s max.) 7.5 VDC min. / 8 VDC typ. / 8.8 VDC max. 15.5 VDC min. / 16 VDC typ. / 17.5 VDC max. 32 VDC min. / 34 VDC typ. / 35.5 VDC max. 4'000 mA (slow blow) 2'000 mA (slow blow) 1'000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal Pi-Type Output Specifications Output Voltage Adjustment Voltage Set Accuracy Regulation –10% to +20% (24 Vout models) ±10% (other models) (single output models only) (By external trim resistor) - Input Variation (Vmin - Vmax) - Load Variation (10 - 90%) Ripple and Noise (20 MHz Bandwidth) - Cross Regulation (25% / 100% asym. load) - single output - dual output Capacitive Load - single output - dual output See application note: www.tracopower.com/overview/thn20wir Output power must not exceed rated power! ±1% max. single output models: 0.2% max. dual output models: 0.5% max. single output models: 0.1% max. dual output models: 0.8% max. (Output 1) 0.8% max. (Output 2) dual output models: 5% max. 3.3 Vout models: 5.1 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 24 / -24 Vout models: 3.3 Vout models: 5.1 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 24 / -24 Vout models: Minimum Load Temperature Coefficient 75 mVp-p typ. (w/ 22 µF, 25 V X7R) 75 mVp-p typ. (w/ 22 µF, 25 V X7R) 100 mVp-p typ. (w/ 22 µF, 25 V X7R) 100 mVp-p typ. (w/ 22 µF, 25 V X7R) 125 mVp-p typ. (w/ 4.7 µF, 50 V X7R) 100 / 100 mVp-p typ. (w/ 10 µF, 25 V X7R) 100 / 100 mVp-p typ. (w/ 10 µF, 25 V X7R) 125 / 125 mVp-p typ. (w/ 4.7 µF, 50 V X7R) 8'000 µF max. 5'000 µF max. 850 µF max. 700 µF max. 220 µF max. 500 / 500 µF max. 350 / 350 µF max. 100 / 100 µF max. Not required ±0.02 %/K max. All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 28, 2023 Page 2 / 5 THN 20WIR Series, 20 Watt Hold-up Time Start-up Time Short Circuit Protection Output Current Limitation Overvoltage Protection Transient Response 10 ms min. (acc. to EN 50155 Class S2, see application note for ext. capacitor calculation: www.tracopower.com/info/holdup_en50155.pdf) 30 ms typ. / 40 ms max. Continuous, Automatic recovery 170% typ. of Iout max. 110 - 164% of Vout nom. 250 µs typ. (25% Load Step) - Response Time Safety Specifications Standards EN 62368-1 IEC 62368-1 UL 62368-1 EN 50155 - IT / Multimedia Equipment - Railway Applications - Certification Documents www.tracopower.com/overview/thn20wir Pollution Degree PD 2 EMC Specifications EMI Emissions EN 50121-3-2 (EMC for Rolling Stock) EN 55032 class A (internal filter) EN 55032 class B (with external filter) EN 55032 class A (internal filter) EN 55032 class B (with external filter) - Conducted Emissions - Radiated Emissions EMS Immunity - Electrostatic Discharge - RF Electromagnetic Field - EFT (Burst) / Surge - Conducted RF Disturbances - PF Magnetic Field External filter proposal: www.tracopower.com/overview/thn20wir (for 110 Vin models a 47 µF / 200 V Nippon chemi-con KXJ capacitor is required to comply with EN 55032 classA) EN 50121-3-2 (EMC for Rolling Stock) Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A EN 61000-4-3, 20 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A Ext. input component: 24 Vin models: 220 µF, 100 V, KY || TVS SMDJ58A 48 Vin models: 220 µF, 100 V, KY 110 Vin models: 150 µF, 200 V, KXJ || TVS SMBJ300A EN 61000-4-6, 10 Vrms, perf. criteria A Continuous: EN 61000-4-8, 100 A/m, perf. criteria A 1 s: EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges - Operating Temperature Power Derating - Case Temperature - Storage Temperature - High Temperature Over Temperature Protection Switch Off - Protection Mode - Measurement Point Cooling System 95% max. (non condensing) –40°C to +85°C –40°C to +90°C (with Heat Sink) +105°C max. –55°C to +125°C Depending on model See application note: www.tracopower.com/overview/thn20wir 105°C min. / 115°C typ. / 130°C max. (Automatic recovery at 100°C typ.) Case Natural convection (20 LFM) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 28, 2023 Page 3 / 5 THN 20WIR Series, 20 Watt Remote Control - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Isolation Test Voltage - Input to Output, 60 s - Input to Case, 60 s - Output to Case, 60 s Isolation Resistance Isolation Capacitance Reliability Washing Process - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF Environment - Vibration - Mechanical Shock - Thermal Shock - Flammability On: 3.0 to 15 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 2.5 mA typ. -0.5 to 1.0 mA 5'000 m max. 230 - 310 kHz (PWM) (24 & 48 Vin, 3.3 & 5.1 Vout models) 290 - 370 kHz (PWM) (24 & 48 Vin, other models) 210 - 270 kHz (PWM) (110 Vin, 3.3 & 5.1 Vout models) 260 - 340 kHz (PWM) (110 Vin, other models) Functional Insulation 3'000 VDC (110 Vin models) 2'250 VDC (other models) 2'250 VDC (110 Vin models) 1'600 VDC (other models) 2'250 VDC (110 Vin models) 1'600 VDC (other models) 1'000 MΩ min. 2'000 pF max. 1'200'000 h (MIL-HDBK-217F, ground benign) According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf MIL-STD-810F EN 61373 MIL-STD-810F EN 61373 MIL-STD-810F EN 45545-2 www.tracopower.com/info/en45545-declaration.pdf Housing Material Base Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Copper Non-conductive FR4 (UL 94 V-0 rated) Silicone (UL 94 V-0 rated) Copper Nickel (2 - 3 µm) Tin (3 - 5 µm), matte Metal Case PCB Mount THD (Through-Hole Device) 1" x 1" Lead-Free Wave Soldering 260°C / 6 s max. 16 g Weight Thermal Impedance 15.5 K/W typ. (without heatsink) 12.3 K/W typ. (with heatsink THN-HS2) 10.7 K/W typ. (with heatsink THN-HS3) 9.1 K/W typ. (with heatsink THN-HS4) - Case to Ambient Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf - SCIP Reference Number Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) 3ab574be-5dc2-42ab-a0ef-a6eed2e2be7e All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 28, 2023 Page 4 / 5 THN 20WIR Series, 20 Watt Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/thn20wir Outline Dimensions 7.62 5.08 10.2 Ø1.0 (0.300) (0.200) (0.40) (0.04) 6 (0.800) Bottom view 20.32 1 (1.00) 2 25.4 3 Pinout 4 5 10.16 10.16 5.6 9.9 (0.400) (0.400) (0.22) (0.39) 25.4 (1.00) Pin Single Dual 1 +Vin (Vcc) +Vin (Vcc) 2 –Vin (GND) –Vin (GND) 3 Remote On/Off Remote On/Off 4 +Vout +Vout 5 Trim Common 6 –Vout –Vout Dimensions in mm (inch) Tolerances: x.x ±0.5 (±0.02) x.xx ±0.25 (±0.01) Pin diameter ±0.1 (±0.004) © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. September 28, 2023 Page 5 / 5
THN 20-2413WIR 价格&库存

很抱歉,暂时无法提供与“THN 20-2413WIR”相匹配的价格&库存,您可以联系我们找货

免费人工找货
THN 20-2413WIR
  •  国内价格 香港价格
  • 1+463.238731+57.46455
  • 10+425.7871610+52.81870
  • 25+411.7288125+51.07477
  • 50+401.4087850+49.79458
  • 100+391.34027100+48.54558
  • 250+342.34191250+42.46736

库存:14